@@ -27,7 +27,7 @@ namespace ModbusObjectConsoleApp
|
||||
myModbusObject.MyProperty11 = new bool[] { false, true, false, true, false, true, false, true, false };//直接赋值多线圈
|
||||
|
||||
myModbusObject.MyProperty3 = 1;//直接赋值保持寄存器
|
||||
myModbusObject.MyProperty33 = new short[] {1,2,3,4,5,6,7,8,9 };//直接赋值保持寄存器
|
||||
myModbusObject.MyProperty33 = new short[] { 1, 2, 3, 4, 5, 6, 7, 8, 9 };//直接赋值保持寄存器
|
||||
|
||||
Console.WriteLine(myModbusObject.MyProperty1.ToJsonString());
|
||||
Console.WriteLine(myModbusObject.MyProperty11.ToJsonString());
|
||||
@@ -51,7 +51,13 @@ namespace ModbusObjectConsoleApp
|
||||
//监听端口
|
||||
.SetListenIPHosts(7808)
|
||||
//设置数据存储区,即线圈、离散输入、保持寄存器、输入寄存器
|
||||
.SetModbusDataLocater(new ModbusDataLocater(10, 10, 10, 10))
|
||||
.SetModbusDataLocater(new ModbusDataLocater(10, 10, 10, 10)
|
||||
{
|
||||
Coils = new DataPartition<bool>(1000, new bool[10]),
|
||||
DiscreteInputs = new DataPartition<bool>(1000, new bool[10]),
|
||||
HoldingRegisters = new DataPartition<byte>(1000, new byte[20]),
|
||||
InputRegisters = new DataPartition<byte>(1000, new byte[20])
|
||||
})
|
||||
);
|
||||
service.Start();
|
||||
Console.WriteLine("服务已启动");
|
||||
@@ -80,7 +86,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.Coils, StartAddress = 0, Timeout = 1000)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.Coils, StartAddress = 1000, Timeout = 1000)]
|
||||
public bool MyProperty1
|
||||
{
|
||||
get { return this.GetValue<bool>(); }
|
||||
@@ -93,7 +99,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、数量
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.Coils, StartAddress = 1, Timeout = 1000, Quantity = 9)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.Coils, StartAddress = 1001, Timeout = 1000, Quantity = 9)]
|
||||
public bool[] MyProperty11
|
||||
{
|
||||
get { return this.GetValueArray<bool>(); }
|
||||
@@ -108,7 +114,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.DiscreteInputs, StartAddress = 0, Timeout = 1000)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.DiscreteInputs, StartAddress = 1000, Timeout = 1000)]
|
||||
public bool MyProperty2
|
||||
{
|
||||
get { return this.GetValue<bool>(); }
|
||||
@@ -120,7 +126,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、数量
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.DiscreteInputs, StartAddress = 1, Timeout = 1000, Quantity = 9)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.DiscreteInputs, StartAddress = 1001, Timeout = 1000, Quantity = 9)]
|
||||
public bool MyProperty22
|
||||
{
|
||||
get { return this.GetValue<bool>(); }
|
||||
@@ -134,7 +140,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、端序
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.HoldingRegisters, StartAddress = 0, Timeout = 1000, EndianType = TouchSocket.Core.EndianType.Big)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.HoldingRegisters, StartAddress = 1000, Timeout = 1000, EndianType = EndianType.Big)]
|
||||
public short MyProperty3
|
||||
{
|
||||
get { return this.GetValue<short>(); }
|
||||
@@ -147,7 +153,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、端序、数组长度
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.HoldingRegisters, StartAddress = 1, Timeout = 1000, EndianType = TouchSocket.Core.EndianType.Big, Quantity = 9)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.HoldingRegisters, StartAddress = 1001, Timeout = 1000, EndianType = TouchSocket.Core.EndianType.Big, Quantity = 9)]
|
||||
public short[] MyProperty33
|
||||
{
|
||||
get { return this.GetValueArray<short>(); }
|
||||
@@ -162,7 +168,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、端序
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.InputRegisters, StartAddress = 0, Timeout = 1000, EndianType = TouchSocket.Core.EndianType.Big)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.InputRegisters, StartAddress = 1000, Timeout = 1000, EndianType = EndianType.Big)]
|
||||
public short MyProperty4
|
||||
{
|
||||
get { return this.GetValue<short>(); }
|
||||
@@ -174,7 +180,7 @@ namespace ModbusObjectConsoleApp
|
||||
/// 配置:站号、数据区、起始地址、超时时间、端序、数组长度
|
||||
/// </para>
|
||||
/// </summary>
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.InputRegisters, StartAddress = 0, Timeout = 1000, EndianType = TouchSocket.Core.EndianType.Big, Quantity = 10)]
|
||||
[ModbusProperty(SlaveId = 1, Partition = Partition.InputRegisters, StartAddress = 1000, Timeout = 1000, EndianType = EndianType.Big, Quantity = 10)]
|
||||
public short[] MyProperty44
|
||||
{
|
||||
get { return this.GetValueArray<short>(); }
|
||||
|
||||
Reference in New Issue